- Out-of-Stock
The Measurement ComputingE-1608 is an ethernet-based DAQ device and features 8 SE/4 DIFF analog inputs, 16-bit resolution, 250 kS/s sample rate, two 16-bit analog outputs, eight digital I/O, and one 32-bit counter input. The device supports input ranges of ±10 V, ±5 V, ±2 V, and ±1 V that are software-selectable per channel.
The E-1608 has a built-in 10/100 BASE-T auto-negotiation, high-speed communication port. The networking protocols are TCP/IP and UDP. Once connected to the network, the device can be remotely accessed and configured through software from anywhere on the network. Only one user at a time can access the E-1608. Software is required to actively communicate with the E-1608 over Ethernet. The device does not operate as a standalone data logger. The device is externally powered via an included power supply.
The E-1608 has two 16-bit, software-paced analog outputs that can be updated at a rate of 500 S/s. The output range is fixed at ±10 V.
The E-1608 has an external digital trigger input. The trigger mode is software-selectable for edge- or level-sensitive mode. Edge-sensitive mode can be configured for either rising or falling edge. Level-sensitive mode can be configured for either high or low level. The default setting at power up is edge-sensitive, rising edge.
Eight bidirectional digital I/O bits are individually-configurable for input or output. The digital I/O terminals can detect the state of any TTL-level input. Bits can be configured for pull-up (+5V) or pull-down (0 V) with an onboard jumper.
One 32-bit event counter can count TTL pulses. The counter accepts inputs of up to 10 MHz. The E-1608 has one external clock input and one clock output for analog inputs.
Software support includes DAQami, an optional out-of-the-box application for data logging, visualization, and signal generation. Data can be viewed in real-time or post-acquisition on user-configurable displays. Drivers are included for the most popular applications and programming languages including Visual C++®, Visual C#®, Visual Basic®.NET, DASYLab®, LabVIEW™, MATLAB®, and Python™.
Ethernet Cable 1M
Multifunctional computer attachment with USB type C interface. It can operate as a 2-channel oscilloscope, 16-channel logic state analyser, signal generator or programmable power supply. Comes with BNC adapter and oscilloscope probes and Mini Grabber clips. Digilent 471-060
No product available!
No product available!
No product available!
No product available!
No product available!
No product available!
No product available!
No product available!
No product available!
No product available!
No product available!
No product available!
No product available!
No product available!
No product available!
No product available!
DAQ device based on Ethernet communication and equipped with 8 SE/4 DIFF analog inputs, two analog outputs, 8 digital inputs/outputs and one 32-bit counter. It offers 16-bit resolution and a sampling rate of 250 kS/s. Digilent 6069-410-016