zł5.60 tax excl.
Module with LPG gas concentration sensor (MQ-6) in the range of 200 - 10,000 ppm. The module has an analogue output and a digital output triggered by exceeding the threshold of sensitivity. modMQ-6
Module with MQ-6 sensor that detects the concentration of LPG gas in the air.
Two outputs - analog and digital with adjustable sensitivity using a potentiometer.

Data sheet
Manufacturer BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Responsible person BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
The MQ-6 sensor allows the measurement of LPG, propane and isobutane. The measuring range of the sensor is in the range of 300 - 10.000 ppm, while the output receives an analog signal.
The module with a smoke sensor and flammable gases (MQ-2) allows the measurement of gas concentrations such as natural gas, hydrogen as well as smoke and ethanol. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity. modMQ-2
The module with an alcohol sensor (MQ-3), allows you to measure the concentration of ethanol in the air. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
The module with a methane concentration sensor (MQ-4) in the range up to 10,000 ppm, has an analogue output and an output triggered by exceeding the threshold of sensitivity.
The module with the natural gas and LPG concentration sensor (modMQ-5) allows the measurement of the concentration of natural gas, carbon monoxide, alcohol and methane. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
The module with the sensor for the measurement of the concentration of carbon monoxide (MQ-7), allows the measurement of the concentration of carbon (CO) in the air. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
The MQ-8 module allows the measurement of hydrogen concentration in the air. It has an analogue output and an output triggered by exceeding the threshold of sensitivity.
No product available!
Module with a knock-on sensor for measurement of methane, propane and carbon monoxide (MQ-9) concentrations. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
The module with an alcohol sensor (MQ-3), allows you to measure the concentration of ethanol in the air. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
The module with a methane concentration sensor (MQ-4) in the range up to 10,000 ppm, has an analogue output and an output triggered by exceeding the threshold of sensitivity.
The module with the natural gas and LPG concentration sensor (modMQ-5) allows the measurement of the concentration of natural gas, carbon monoxide, alcohol and methane. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
Module with LPG gas concentration sensor (MQ-6) in the range of 200 - 10,000 ppm. The module has an analogue output and a digital output triggered by exceeding the threshold of sensitivity. modMQ-6
The module with the sensor for the measurement of the concentration of carbon monoxide (MQ-7), allows the measurement of the concentration of carbon (CO) in the air. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
The MQ-8 module allows the measurement of hydrogen concentration in the air. It has an analogue output and an output triggered by exceeding the threshold of sensitivity.
No product available!
Module with a knock-on sensor for measurement of methane, propane and carbon monoxide (MQ-9) concentrations. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
Adapter for MQ gas sensor with potentiometer for analog signal calibration. MOD 72
MQ-135 Gas Sensor
Gravity: Analog Infrared CO2 Sensor is a high precision analogue CO2 sensor. It measures CO2 content in the range of 0 ... 5000ppm and is compatible with all devices with ADC function. DFRobot SEN0219
Gravity: UART Infrared CO2 Sensor is a high precision CO2 sensor. It uses the UART interface for communication. It allows to measure CO2 content in the air in the range of 0 ... 50000ppm. DFRobot SEN0220
The sensor is designed for indoor air quality testing. The main gas detected is carbon monoxide, alcohol, acetone, thinner, formaldehyde and other slightly toxic gases. It is compatible with 5V and 3.3V power supply. Seeed Studio 101020078
MH-Z16 carbon dioxide sensor with Grove connector. It communicates via the UART interface. Seeed Studio 101020067
Gravity: Formaldehyde (HCHO) Sensor is a module for measuring the concentration of formaldehyde (methane) in the air. It can be supplied with voltage in the range of 3.3 ... 6V. DFRobot SEN0231
Digital gas sensor solution that senses a wide range of Total Volatile Organic Compounds (TVOCs), including equivalent carbon dioxide (eCO2) and metal oxide (MOX) levels, intended for indoor air quality monitoring in personal devices such as watches and phones, but we’ve put it on a breakout board so you can use it as a regular I2C device. SEN-14193
The module allows the detection of volatile organic compounds (VOC) in the air, based on Winsen\'s WSP2110 system. Allows for detection in the air; formaldehyde (HCHO), methane, benzene, toluene, alcohol, etc. The sensor output is an analog signal. Seeed studio 101020001
Module with LPG gas concentration sensor (MQ-6) in the range of 200 - 10,000 ppm. The module has an analogue output and a digital output triggered by exceeding the threshold of sensitivity. modMQ-6