

Module with MQ-8 sensor enabling detection of hydrogen concentration in the air.
Two outputs - analog and digital with adjustable sensitivity using a potentiometer.
Data sheet
Manufacturer BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Responsible person BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
The MQ-8 sensor allows the measurement of hydrogen concentration in the air. The measuring range of the sensor is in the range of 100 - 10,000 ppm.
The module with a smoke sensor and flammable gases (MQ-2) allows the measurement of gas concentrations such as natural gas, hydrogen as well as smoke and ethanol. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity. modMQ-2
The module with an alcohol sensor (MQ-3), allows you to measure the concentration of ethanol in the air. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
The module with a methane concentration sensor (MQ-4) in the range up to 10,000 ppm, has an analogue output and an output triggered by exceeding the threshold of sensitivity.
The module with the natural gas and LPG concentration sensor (modMQ-5) allows the measurement of the concentration of natural gas, carbon monoxide, alcohol and methane. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
Module with LPG gas concentration sensor (MQ-6) in the range of 200 - 10,000 ppm. The module has an analogue output and a digital output triggered by exceeding the threshold of sensitivity. modMQ-6
The module with the sensor for the measurement of the concentration of carbon monoxide (MQ-7), allows the measurement of the concentration of carbon (CO) in the air. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
Module with a knock-on sensor for measurement of methane, propane and carbon monoxide (MQ-9) concentrations. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
Sensor that detects the concentration of chlorine. Equipped with a factory calibrated probe. It communicates via the I2C interface, UART or analog output. DFRobot SEN0468
No product available!
Module with a knock-on sensor for measurement of methane, propane and carbon monoxide (MQ-9) concentrations. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
Gravity: Formaldehyde (HCHO) Sensor is a module for measuring the concentration of formaldehyde (methane) in the air. It can be supplied with voltage in the range of 3.3 ... 6V. DFRobot SEN0231
Module with LPG gas concentration sensor (MQ-6) in the range of 200 - 10,000 ppm. The module has an analogue output and a digital output triggered by exceeding the threshold of sensitivity. modMQ-6
Module with CO2, temperature and humidity sensor SCD-40. Equipped with a STEMMA QT connector, it communicates via the I2C interface. Adafruit 5187
Module with nitrogen dioxide sensor made in MEMS technology. It allows gas detection in the range of 0.1 to 10 ppm and has an analog output. DFRobot SEN0574
The MQ-7 sensor allows you to measure the concentration of carbon monoxide (carbon monoxide). The measuring range of the sensor is in the range of 10 - 10,000 ppm
Module with a VOC sensor (volatile organic compounds) made in MEMS technology. It allows gas detection in the range of 5 to 500 ppm and has an analog output. DFRobot SEN0566
Pololu MQ Gas Sensor Carrier
Module with an analog MQ4 methane sensor. It is powered with the voltage of 5 V and has an analog output. DFRobot SEN0129
The SCD-41 CO2, temperature and humidity sensor module provides high accuracy readings. It is equipped with a Qwiic connector and communicates via an I2C interface. SparkFun SEN-22396
The module with the natural gas and LPG concentration sensor (modMQ-5) allows the measurement of the concentration of natural gas, carbon monoxide, alcohol and methane. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
ENS160 gas sensor module to measure the concentration of carbon dioxide (eCO2) and volatile organic compounds (TVOC) in the air. It communicates via an I2C or SPI interface. SparkFun SEN-20844
The module allows the detection of volatile organic compounds (VOC) in the air, based on Winsen\'s WSP2110 system. Allows for detection in the air; formaldehyde (HCHO), methane, benzene, toluene, alcohol, etc. The sensor output is an analog signal. Seeed studio 101020001
Volatile gas sensor module, including LPG, natural gas, natural gas
Module with CO2, temperature and humidity sensor SCD-41. Equipped with a Qwiic/STEMMA QT connector, it communicates via the I2C interface. Pimoroni PIM587
The MQ-8 module allows the measurement of hydrogen concentration in the air. It has an analogue output and an output triggered by exceeding the threshold of sensitivity.