Module with MQ-8 sensor enabling detection of hydrogen concentration in the air.
Two outputs - analog and digital with adjustable sensitivity using a potentiometer.
Data sheet
Manufacturer BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Responsible person BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
The MQ-8 sensor allows the measurement of hydrogen concentration in the air. The measuring range of the sensor is in the range of 100 - 10,000 ppm.
The module with a smoke sensor and flammable gases (MQ-2) allows the measurement of gas concentrations such as natural gas, hydrogen as well as smoke and ethanol. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity. modMQ-2
The module with an alcohol sensor (MQ-3), allows you to measure the concentration of ethanol in the air. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
The module with a methane concentration sensor (MQ-4) in the range up to 10,000 ppm, has an analogue output and an output triggered by exceeding the threshold of sensitivity.
The module with the natural gas and LPG concentration sensor (modMQ-5) allows the measurement of the concentration of natural gas, carbon monoxide, alcohol and methane. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
Module with LPG gas concentration sensor (MQ-6) in the range of 200 - 10,000 ppm. The module has an analogue output and a digital output triggered by exceeding the threshold of sensitivity. modMQ-6
The module with the sensor for the measurement of the concentration of carbon monoxide (MQ-7), allows the measurement of the concentration of carbon (CO) in the air. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
Module with a knock-on sensor for measurement of methane, propane and carbon monoxide (MQ-9) concentrations. The module has an analogue output and an output triggered by exceeding the threshold of sensitivity.
Air quality sensor module based on the SGP40 system. It communicates via the I2C interface. DFRobot SEN0392
The MQ-5 sensor allows the measurement of alcohol and gas concentrations, such as methane, LPG, and carbon monoxide. Sensor measuring range: up to 10,000 ppm
A sensor that detects the oxygen concentration. Equipped with a factory calibrated probe. It communicates via the I2C interface, UART or analog output. DFRobot SEN0465
Module with ethanol sensor made in MEMS technology. It allows gas detection in the range of 1 to 500 ppm and has an analog output. DFRobot SEN0569
Module with gas sensor designed to monitor indoor air quality. It was based on the AMS CCS811 system that allows the detection of volatile organic compounds (VOCs) in the air. Digilent 410-386
Module with air quality sensor SGP30. It allows you to read the concentration of VOC (TVOC) and eCO2 and communicates via the I2C interface. Pimoroni PIM480
The sensor is designed for indoor air quality testing. The main gas detected is carbon monoxide, alcohol, acetone, thinner, formaldehyde and other slightly toxic gases. It is compatible with 5V and 3.3V power supply. Seeed Studio 101020078
MH-Z16 carbon dioxide sensor with Grove connector. It communicates via the UART interface. Seeed Studio 101020067
Module with an ozone detection sensor that performs measurements in the range of up to 10 ppm with a resolution of 0.01 ppm. The module is equipped with an I2C interface. DFRobot SEN0321
No product available!
A sensor that detects the concentration of hydrogen. Equipped with a factory calibrated probe. It communicates via the I2C interface, UART or analog output. DFRobot SEN0473
No product available!
Integrated BME688 gas, pressure, temperature and humidity sensor in one MEMS housing. The system can be supplied with the voltage of 3.3 V and is equipped with an I2C communication interface. BME688 Breakout Board
The MQ-3 sensor allows you to measure the concentration of alcohol vapors. The measuring range of the sensor is in the range of 0.05 mg / L to 10mg / L, and an analogue signal is obtained at the output.
Module with Sensirion SCD30 sensor, which enables CO2, temperature and humidity measurement. The board is equipped with a Grove connector and communicates via the I2C interface. Seeed Studio 101020634
No product available!
Module with an analog sensor of carbon monoxide and combustible gases (methane, propane) MQ9. It is powered with the voltage of 5 V and has an analog output. DFRobot SEN0134
A sensor that detects the concentration of phosphine. Equipped with a factory calibrated probe. It communicates via the I2C interface, UART or analog output. DFRobot SEN0476
No product available!
The MQ-8 module allows the measurement of hydrogen concentration in the air. It has an analogue output and an output triggered by exceeding the threshold of sensitivity.