zł2,502.54 tax excl.
DAQ device based on Ethernet communication and equipped with 8 SE/4 DIFF analog inputs, two analog outputs, 8 digital inputs/outputs and one 32-bit counter. It offers 16-bit resolution and a sampling rate of 250 kS/s. Digilent 6069-410-016
The Measurement ComputingE-1608 is an ethernet-based DAQ device and features 8 SE/4 DIFF analog inputs, 16-bit resolution, 250 kS/s sample rate, two 16-bit analog outputs, eight digital I/O, and one 32-bit counter input. The device supports input ranges of ±10 V, ±5 V, ±2 V, and ±1 V that are software-selectable per channel.
The E-1608 has a built-in 10/100 BASE-T auto-negotiation, high-speed communication port. The networking protocols are TCP/IP and UDP. Once connected to the network, the device can be remotely accessed and configured through software from anywhere on the network. Only one user at a time can access the E-1608. Software is required to actively communicate with the E-1608 over Ethernet. The device does not operate as a standalone data logger. The device is externally powered via an included power supply.
The E-1608 has two 16-bit, software-paced analog outputs that can be updated at a rate of 500 S/s. The output range is fixed at ±10 V.
The E-1608 has an external digital trigger input. The trigger mode is software-selectable for edge- or level-sensitive mode. Edge-sensitive mode can be configured for either rising or falling edge. Level-sensitive mode can be configured for either high or low level. The default setting at power up is edge-sensitive, rising edge.
Eight bidirectional digital I/O bits are individually-configurable for input or output. The digital I/O terminals can detect the state of any TTL-level input. Bits can be configured for pull-up (+5V) or pull-down (0 V) with an onboard jumper.
One 32-bit event counter can count TTL pulses. The counter accepts inputs of up to 10 MHz. The E-1608 has one external clock input and one clock output for analog inputs.
Software support includes DAQami, an optional out-of-the-box application for data logging, visualization, and signal generation. Data can be viewed in real-time or post-acquisition on user-configurable displays. Drivers are included for the most popular applications and programming languages including Visual C++®, Visual C#®, Visual Basic®.NET, DASYLab®, LabVIEW™, MATLAB®, and Python™.
Ethernet Cable 1M
DAQ device based on USB communication and equipped with 8 single-end analog inputs, two analog outputs, 8 digital I/O and one 32-bit counter. It offers 12-bit resolution and a sampling rate of 100 kS/s. Digilent 6069-410-008
No product available!
DAQ device based on USB communication and equipped with 8 analog SE / DIFF inputs, two analog outputs, 4 digital I/O, two counters and two inputs for encoder support. It offers 18-bit resolution and a sampling rate of 200 kS/s. Digilent 6069-410-014
No product available!
A holder for mounting on a DIN rail dedicated to devices from the BTH-1208LS, E-1608, E-DIO24, USB-200 and WebDAQ series. Digilent 6069-240-005
No product available!
Multifunctional computer attachment with USB type C interface. It can operate as a 2-channel oscilloscope, 16-channel logic state analyser, signal generator or programmable power supply. Comes with BNC adapter and oscilloscope probes and Mini Grabber clips. Digilent 471-060
The 0-25 mm digital micrometer is a reliable tool for professionals that provides precise measurements with easy reading of the results. It is ideal for accurately measuring a variety of objects in workshop or laboratory conditions. YT-72305
DAQ device based on USB communication and equipped with 8 single-end analog inputs, two analog outputs, 8 digital I/O and one 32-bit counter. It offers 12-bit resolution and a sampling rate of 500 kS/s. Digilent 6069-410-009
No product available!
DC analyzer with a voltage measuring range from 4 to 60 V and current up to 100 A. It allows you to measure power, capacity and energy in the circuit
DAQ device based on USB communication and equipped with 8 single-ended or 4 differential analog inputs, 2 analog outputs, 16 digital inputs/outputs and one 32-bit counter. It offers 12-bit resolution and a sampling rate of 50 kS/s per channel. Digilent 6069-410-061
No product available!
A universal calibrator that allows both simulation and measurement of various electrical and thermal parameters. It is able to emulate thermocouple signals and enables accurate measurement of direct voltage (DC), resistance and current, as well as testing and calibration of thermocouples and Pt100 and Cu50 thermoresistance sensors. LB02
The MLC500 meter is a precise inductance and capacitance measuring device, offering a wide measurement range and a convenient, backlit LCD display.
DAQ device based on USB communication and equipped with 8 analog SE/4 DIFF inputs, two analog outputs, 8 digital inputs/outputs and one 32-bit counter. It offers 16-bit resolution and a sampling rate of 50 kS/s. Digilent 6069-410-012
No product available!
Li-Fe battery monitor that can measure voltage, current, power during charging and discharging, and watt-hours consumed and run time. The user can use a mobile application and a computer to control the measuring module. Juntek KG110F
MCC USB-SSR24 is a control module for 24 SSR relays with optical isolation, USB communication, and support for popular programming languages. Digilent 6069-410-200
No product available!
A portable combustible gas detector designed to detect methane, propane, and isobutane. The device features a 2.0" color TFT screen, three alarm modes (audible, visual, and vibrating), and a flexible 36 cm probe for easy access to hard-to-reach areas. A response time of less than 5 seconds and the ability to record up to 30 alarm events ensure fast and precise threat detection. Fnirsi GD-02
No product available!
Portable hardness tester using the Richter hardness principle to measure the hardness of metals. Equipped with a 2.8-inch display and Bluetooth communication. Hantek HT360C
USB-CTR04 is a counter module with 4 inputs, PWM support, up to 48 MHz input frequency, and a high-speed USB interface. Digilent 6069-410-057
No product available!
Tester dedicated to testing parameters in lead-acid batteries. It can check the working status of the battery by testing the starting process, charging process and electric load process, and then quickly and accurately analyze the battery\'s life status. Hantek HT2018B
No product available!
MCC USB-3102 – USB module with 4 voltage/current outputs, 8 digital I/O lines, and a 32-bit counter input. Digilent 6069-410-030
No product available!
DAQ device based on USB communication and equipped with 8 analog SE/4 DIFF inputs, two analog outputs, 8 digital inputs/outputs and one 32-bit counter. It offers 16-bit resolution and a sampling rate of 100 kS/s. Digilent 6069-410-013
No product available!
Quick 492G station designed for testing personal grounding in industrial conditions
DAQ device based on Ethernet communication and equipped with 8 SE/4 DIFF analog inputs, two analog outputs, 8 digital inputs/outputs and one 32-bit counter. It offers 16-bit resolution and a sampling rate of 250 kS/s. Digilent 6069-410-016