zł85.40 tax excl.
Current measurement module with the galvanically isolated Allegro ACS37200LLXTR-200B3 Hall-effect sensor. It provides a ±200 A bidirectional range, 6.6 mV/A sensitivity, 150 kHz bandwidth, and a response time below 4 µs. The large carrier board facilitates high-current connections. Pololu 5792
Current sensor module Pololu 5792 uses the Allegro ACS37200LLXTR-200B3 Hall-effect sensor with a galvanically isolated current path. It provides bidirectional current measurement from -200 A to +200 A, while the extra-low current path resistance of approximately 0.05 mΩ helps minimize voltage drop and power losses. The analog output provides a 150 kHz bandwidth and a response time below 4 µs.
Sensor operates from a 3.15–3.45 V supply, with 3.3 V nominal operation, and provides a sensitivity of 6.6 mV/A. VOUT is centered at approximately 1.65 V at zero current and changes proportionally to the magnitude and direction of the measured current. The module also provides a VREF output and a FAULT output with a user-configurable overcurrent threshold and an approximately 3 µs response time.
Large Carrier version uses a 6-layer PCB with 2 oz copper and provides several options for high-current connections, including holes for M6 or 1/4″ hardware and direct soldering of wires up to 4 AWG. The minimum PCB creepage distance is 10.4 mm, while the sensor IC has a 1097 VRMS working isolation rating. The board measures approximately 35.6 × 30.5 mm.
Manufacturer
Responsible person
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5256
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5257
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5258
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5259
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5260
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5262
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5263
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5270
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5271
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5272
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5273
Large Carrier version current sensor from Pololu, model 5274, based on the ACS72981LLRATR-100B5 IC, designed for measuring current in the range from -100 A to +100 A at a 5 V supply in applications requiring galvanic isolation and analog output. Pololu 5274
Large Carrier version current sensor from Pololu, model 5275, based on the ACS72981LLRATR-100U3 IC, designed for measuring current in the range from 0 A to 100 A at a 3.3 V supply in applications requiring galvanic isolation and analog output. Pololu 5275
Large Carrier version current sensor from Pololu, model 5276, based on the ACS72981LLRATR-100U5 IC, designed for measuring current in the range from 0 A to 100 A at a 5 V supply in applications requiring galvanic isolation and analog output. Pololu 5276
Large Carrier version current sensor from Pololu, model 5277, based on the ACS72981KLRATR-150B3 IC, designed for measuring current in the range from -150 A to +150 A at a 3.3 V supply in applications requiring galvanic isolation and analog output. Pololu 5277
Pololu 5278 Large Carrier current sensor based on the ACS72981KLRATR-150B5 chip, designed for bidirectional current measurement from -150 A to +150 A with 5 V supply voltage in applications requiring galvanic isolation and an analog output signal. Pololu 5278
Current measurement module with the galvanically isolated Allegro ACS37200LLXTR-200B3 Hall-effect sensor. It provides a ±200 A bidirectional range, 6.6 mV/A sensitivity, 150 kHz bandwidth, and a response time below 4 µs. The large carrier board facilitates high-current connections. Pololu 5792