

Probe for measuring AC currents up to 1000 A. Uses standard BNC interface and can be connected to an oscilloscope or a multimeter. It works in the frequency range from 10 Hz to 100 kHz, has three measuring ranges: 10, 100 and 1000 A. The jaw spacing allows you to measure the current flowing in cables with a maximum diameter of 52 mm. It can be used in industry, automotive electronics, power supplies and inverters. Dedicated to Micsig devices.
Manufacturer BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Responsible person BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Probe for measuring direct and alternating current up to 100 A. It works in the 800 kHz band, it can be connected to the oscilloscope through the BNC connector. Powered by USB. Micsig CP2100A
No product available!
A portable tablet oscilloscope with a 10.1 inch LCD display and a touch screen. It has four channels and has good measurement parameters: 300 MHz bandwidth, 2 GSa/s sampling rate and 220 Mpts memory buffer. Micsig TO3004
The Hantek PP-300 is an oscilloscope probe with a bandwidth of 300 MHz, designed for precise measurement of high-frequency signals. It is compatible with a wide range of digital and analog oscilloscopes and features a switchable attenuation setting between 1× and 10×, allowing flexible adaptation to various applications. Thanks to its ergonomic design and robust construction, the probe offers user comfort and durability for everyday use in laboratory environments.
A probe tip with attenuation factor of 200X. Dedicated to Micsig probes from the SigOFIT series operating in the frequency band of 100MHz, 200MHz and 350MHz. Micsig OP200-3
No product available!
Oscilloscope probe designed to analyze signals generated by the ignition coil in car engines. It is compatible with most digital oscilloscopes. Hantek HT25COP
A probe tip with attenuation factor of 10000X. Dedicated to Micsig probes from the SigOFIT series operating in the 800 MHz and 1 GHz frequency band. Micsig OP10000-1G
No product available!
6-wire test leads that allow the oscilloscope to be connected to various components in the engine compartment without stripping or puncturing the insulation and without risking damage to the connectors. Hantek HT306-2.8mm
No product available!
High-voltage differential probe. It has good measurement characteristics: a bandwidth of 100 MHz and an operating voltage of up to 1300 V. The probe has two attenuation coefficients: 50X and 500X. Hantek HT8100
No product available!
The Hantek PP-250 is an oscilloscope probe with a bandwidth of 250 MHz, designed for precise high-frequency signal measurements. Equipped with a 1×/10× attenuation switch, it allows flexible adjustment for various measurement applications. Its ergonomic design and solid construction ensure comfortable use and long-lasting durability in everyday laboratory work.
Oscilloscope probe designed for the analysis of signals generated by the ignition coil in automotive engines. It is compatible with most digital oscilloscopes. Hantek HT25
Test probe tip with 20X attenuation factor. Dedicated to Micsig probes from the SigOFIT series operating in the 800 MHz and 1 GHz frequency band. Micsig OP20-1G
No product available!
Test probe tip with 1000X attenuation factor. Dedicated to Micsig probes from the SigOFIT series operating in the 350 MHz and 500 MHz frequency bands. Micsig OP1000-5
No product available!
Rogowski-type current probe for precise measurements of alternating currents with a frequency of up to 30 MHz. Thanks to the flexible coil of 1.6 mm thickness and almost zero impedance introduced, it is perfect for work in hard-to-reach places of power systems. The integrated amplifier and BNC interface enable accurate measurements and easy integration with oscilloscopes, making it an ideal tool for R&D laboratories and power electronics services. Micsig RCP600XS
No product available!
Universal oscilloscope probe with BNC plug and 10:1 voltage divider. It has a frequency range of 60 MHz and allows you to perform measurements with a maximum voltage of up to 600 V.
BNC connector cable (adapter) for minigrabber clips. It enables the connection of the tested system with an oscilloscope
No product available!
Micsig P130A is a reliable oscilloscope probe, ideal for precise measurements in high-voltage systems with a wide frequency range
Probe for measuring direct and alternating current up to 100 A. It works in the 800 kHz band, it can be connected to the oscilloscope through the BNC connector. Powered by USB. Micsig CP2100A
No product available!
A probe tip with attenuation factor of 100X. Dedicated to Micsig probes from the SigOFIT series operating in the 500 MHz frequency band. Micsig OP100-5
No product available!
Probe for measuring AC currents up to 1000 A. It works in the range from 10 Hz to 100 kHz, it can be connected to the oscilloscope through the BNC connector. Micsig ACP1000