A probe with a Rogowski coil dedicated to measuring current in a wide frequency range. It is characterized by universal application, and at the same time it is easy to use in hard-to-reach parts of the circuit. The measuring coil is flexible, which means that measurements can be made without modifying the circuit under test. The probe is safe and convenient to use. It offers a current measurement of up to 500 A in the frequency range from 15 to 300 kHz. It is powered directly via the Micsig UPI interface or via USB for other oscilloscopes.
Manufacturer
Responsible person
A portable tablet oscilloscope with a 10.1 inch LCD display and a touch screen. It has four channels and has good measurement parameters: 300 MHz bandwidth, 2 GSa/s sampling rate and 220 Mpts memory buffer. Micsig TO3004
A portable oscilloscope for automotive applications with an 8-inch LCD display and a touch screen. It has four channels and has good measurement parameters: 100 MHz bandwidth, 1 GSa/s sampling rate and 70 Mpts memory buffer. Micsig SATO1004 Standard Kit
Micsig differential probe from the DP series designed for high-voltage and differential signal measurements. Offers 100 MHz bandwidth and supports voltage measurements up to 700 V. Features a standard BNC connector and USB Type-C power supply. The current product revision includes a new enclosure with three function buttons. Micsig DP700
The RIGOL PLA3204 analyzes logic signals with a maximum time resolution of 5 ns, ensuring high compatibility with various voltage standards. It is indispensable for diagnostics and testing of digital circuits using RIGOL MHO5000 and DHO5000 series oscilloscopes. RIGOL PLA3204
Micsig MSP510 passive oscilloscope probe with a 500 MHz bandwidth and 1:10 attenuation designed for precise high-frequency signal measurements. Compatibility with the BNC standard and compensation adjustment make it a universal tool for laboratories and electronics workshops.
The Micsig CP3008 probe is designed for precise measurement of AC/DC currents in high-voltage and high-current circuits. It is used in the analysis of switching power supplies, power converters, inverters, and testing of devices with high current loads.
No product available!
The Zeenko 3 dB SMA attenuator is a solid and precise component for RF measurement paths, useful in diagnostics, calibration and protecting devices such as the tinySA, nanoVNA or RF generators. It enables safe measurements and improves impedance matching quality over a wide frequency range.
No product available!
The Zeenko 6 dB SMA attenuator is a solid and precise component for RF measurement paths, useful in diagnostics, calibration and protecting devices such as the tinySA, nanoVNA or RF generators. It enables safe measurements and improves impedance matching quality over a wide frequency range.
No product available!
The Zeenko 20 dB SMA attenuator is a solid and precise component for RF measurement paths, useful in diagnostics, calibration and protecting devices such as the tinySA, nanoVNA or RF generators. It enables safe measurements and improves impedance matching quality over a wide frequency range.
No product available!
The Zeenko 30 dB SMA attenuator is a solid and precise component for RF measurement paths, useful in diagnostics, calibration and protecting devices such as the tinySA, nanoVNA or RF generators. It enables safe measurements and improves impedance matching quality over a wide frequency range.
The Zeenko N 10 dB attenuator is a reliable accessory for any RF system user – from amateurs to professionals. It enables safe and precise measurements and provides better signal matching in the signal path. Thanks to its high durability (up to 5 W), it is suitable for a wide range of laboratory and field applications.
This current probe is designed for measuring DC and AC current in power electronics systems and switching power supplies. It offers a 10 MHz DC bandwidth, a rise time of ≤ 46 ns, and two measurement ranges: 30 A and 150 A RMS, with a maximum peak current of up to 300 A. The device provides high measurement accuracy of ±1% and a resolution of up to 10 mA in the lower range. The BNC connector ensures compatibility with many oscilloscopes, and the 20 mm jaws enable current measurements in larger wires. Micsig CP1510
No product available!
This current probe is designed for measuring DC and AC current in power electronics systems and switching power supplies. It offers a 5 MHz DC bandwidth, a rise time of ≤ 70 ns, and two measurement ranges: 50 A and 300 A RMS, with a maximum peak current of up to 500 A. The device provides high measurement accuracy of ±1% and a resolution of up to 10 mA in the lower range. The BNC connector ensures compatibility with many oscilloscopes, and the 20 mm jaws enable current measurements in larger wires. Micsig CP3005
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 60 A, offering a wide bandwidth from 70 Hz to 30 MHz and a sensitivity of 100 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP60XS-80
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 120 A, offering a wide bandwidth from 34 Hz to 30 MHz and a sensitivity of 50 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP120XS-80
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 300 A, offering a wide bandwidth from 10 Hz to 30 MHz and a sensitivity of 20 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP300XS-80
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 600 A, offering a wide bandwidth from 8 Hz to 30 MHz and a sensitivity of 10 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP600XS-80
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 1200 A, offering a wide bandwidth from 5 Hz to 30 MHz and a sensitivity of 5 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP1200XS-80
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 3000 A, offering a wide bandwidth from 4 Hz to 30 MHz and a sensitivity of 2 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP3000XS-80
No product available!
A probe with a Rogowski coil dedicated to measuring current in a wide frequency range. Measurements can be made without modifying the circuit under test. Micsig RCP500