zł77.15 tax excl.
Laser sensor of air pollution with particles PM1,0, PM2.5 and PM10. It allows for precise analysis of the amount of pollutants in the environment, has small dimensions and a built-in silent transfer fan. Data is output to the UART interface. Planter PMSA003-C
Laser sensor of air pollution with particles PM1.0, PM2.5 and PM10. It allows for precise analysis of the amount of pollutants in the environment, has small dimensions and a built-in silent transfer fan. Data is output to the UART interface.
The module has a blue protective film (visible in the pictures)
The voltage on the RX, TX, RESET, SET signal lines must not exceed 3.3 V. If you want to control the module with a higher voltage, we recommend using a logic converter, eg KAmodLVC .
| Contact | Name | Description |
|---|---|---|
| 1 | VCC | + 5V |
| 2 | VCC | + 5V |
| 3 | GND | Mass |
| 4 | GND | Mass |
| 5 | RESET | Resetting (when low) |
| 6 | NC | - |
| 7 | RX | Data collection line |
| 8 | NC | - |
| 7 | TX | Data transmission line |
| 8 | SET | Sleep (when low) |
Data sheet
Manufacturer BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Responsible person BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Laser sensor of air pollution with particles PM1,0, PM2.5 and PM10. It allows for precise analysis of the amount of pollutants in the environment, has small dimensions and a built-in silent transfer fan. Data is output to the UART interface. PMS3003
PMS7003 is a kind of digital and universal particle concentration sensor, which can be used to obtain the number of suspended particles in the air, i.e. the concentration of particles, and output them in the form of digital interface
No product available!
Adapter form IDC10 1,27 mm used on laser dust sensor PMS7003 to 2,54 mm goldpin. It helps with connecting sensor to standard breadboard or development boards (Arduino, STM32 etc.). It can be connected to PMS7003 easily, as connector fit with sensor\'s outputs
Module with sensors of environmental parameters. It allows you to measure temperature, humidity and pressure as well as CO2 and VOC concentration. DFRobot SEN0335
PMS7003 is a kind of digital and universal particle concentration sensor, which can be used to obtain the number of suspended particles in the air, i.e. the concentration of particles, and output them in the form of digital interface
No product available!
Laser dust sensor is a digital universal particle concentration sensor,it can be used to obtain the number of suspended particulate matter in a unit volume of air within 0.3 to 10 microns, namely the concentration of particulate matter, and output with digital interface, also can output quality data of per particle. DFRobot SEN0177
BME688 integrated gas, pressure, temperature and humidity sensor module housed in a single MEMS package. It features a Grove connector and communicates via an I2C or SPI interface. Seeed Studio 114992989
Module with air quality sensor SGP30. The board is equipped with a Grove connector and communicates via the I2C interface. Seeed Studio 101020512
No product available!
Bosch environmental sensor that measures temperature, humidity, pressure and air quality based on gas analysis (VOC, VSC, CO, H₂). It is characterized by low power consumption, high resistance to moisture and the ability to train AI algorithms to identify specific pollutants. It is compatible with Raspberry Pi, Raspberry Pi Pico, Breakout Garden and Qwiic/STEMMA QT systems, which allows easy integration without soldering. Pimoroni PIM769
No product available!
Module with gas sensor designed to monitor indoor air quality. It was based on the AMS CCS811 system that allows the detection of volatile organic compounds (VOCs) in the air. Digilent 410-386
Module dedicated to projects related to air quality monitoring. It uses the popular ENS160 and BME280 chips and provides a variety of environmental data such as Air Quality Index (AQI), TVOCs levels, CO2 equivalent (eCO2), atmospheric pressure, humidity and temperature. It communicates via the I2C interface and offers two Qwiic connectors. SparkFun SEN-22858
A sensor used to detect air pollutants by measuring VOCs and gases such as ammonia or hydrogen sulfide. It is used in various areas, such as the food industry, chemical industry, air quality control in laboratories and environmental monitoring. Figaro TGS2602
Digital gas sensor solution that senses a wide range of Total Volatile Organic Compounds (TVOCs), including equivalent carbon dioxide (eCO2) and metal oxide (MOX) levels, intended for indoor air quality monitoring in personal devices such as watches and phones, but we’ve put it on a breakout board so you can use it as a regular I2C device. SEN-14193
A sensor used to detect pollutants in the air by measuring gases such as hydrogen, ethanol and carbon monoxide. It is used in various areas, such as the food industry, chemical industry, air quality control in laboratories and environmental monitoring. Figaro TGS2600
Module with PM2.5 HM3301 dust sensor. The board is equipped with a Grove connector and communicates via the I2C interface. Seeed Studio 101020613
The SEN55 sensor module from Sensirion, which combines a sensor allowing the measurement of particulate matter, volatile organic compounds, NOx, humidity and temperature in one housing. SparkFun SEN-23715
Wireless sensor with LoRaWAN network communication. Dedicated to long-distance industrial data acquisition with a wide measurement range of CO2 from 400 to 10000 ppm, temperature from -40°C to 85°C and humidity from 0 to 100% RH. Seeed Studio 114992869
Laser sensor of air pollution with particles PM1,0, PM2.5 and PM10. It allows for precise analysis of the amount of pollutants in the environment, has small dimensions and a built-in silent transfer fan. Data is output to the UART interface. PMS3003
Laser sensor of air pollution with particles PM1,0, PM2.5 and PM10. It allows for precise analysis of the amount of pollutants in the environment, has small dimensions and a built-in silent transfer fan. Data is output to the UART interface. Planter PMSA003-C