zł77,234.96 tax excl.
Insulated fiber optic probe with a measuring range up to 2500 V. It works in the band up to 800 MHz, it can be connected to the oscilloscope via the BNC connector. Comes with a 10X attenuation tip. Micsig MOIP800P
An isolated fiber optic probe that works in the frequency band up to 800 MHz. It uses a standard BNC interface and can be connected to an oscilloscope or multimeter. Utilizing SigOFIT optical isolation technology, it offers high accuracy and excellent suppression of oscillations caused by high-frequency common-mode noise.

The probe has excellent amplitude-frequency characteristics and the DC gain accuracy is less than 1%. The maximum noise floor in this range is 1.41 mVrms and the zero drift is less than 500 μV. It is an excellent choice for the study of third generation semiconductors and devices based on SiC and GaN. The probe test leads are short and have an input capacitance of less than 3 pF when transmitted via coaxial cable, allowing for very safe testing.

Unlike traditional differential probes that can only test high-voltage signals, the SigOFIT can be used with a variety of tips to test differential mode signals from ±1.25 V to ±2500 V, achieving full output range and very high signal to ratio noise. It will be used in industry, automotive electronics, when servicing power supplies and inverters. It is dedicated to Micsig devices.
Manufacturer BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Responsible person BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Test probe tip with 20X attenuation factor. Dedicated to Micsig probes from the SigOFIT series operating in the 800 MHz and 1 GHz frequency band. Micsig OP20-1G
No product available!
Test probe tip with 50X attenuation factor. Dedicated to Micsig probes from the SigOFIT series operating in the 800 MHz and 1 GHz frequency band. Micsig OP50-1G
No product available!
Test probe tip with 1000X attenuation factor. Dedicated to Micsig probes from the SigOFIT series operating in the 800 MHz and 1 GHz frequency band. Micsig OP1000-1G
No product available!
Test probe tip with 2000X attenuation factor. Dedicated to Micsig probes from the SigOFIT series operating in the 800 MHz and 1 GHz frequency band. Micsig OP2000-1G
No product available!
A universal oscilloscope probe with a BNC connector and a 10:1 voltage divider. It has a frequency response of 100 MHz and allows measurements with a maximum voltage of up to 600 V. Hantek PP-150
No product available!
A universal oscilloscope probe with a BNC connector and a 10:1 voltage divider. It has a frequency response of 200 MHz and allows measurements with a maximum voltage of up to 600 V. Hantek PP-200
High-voltage oscilloscope probe with BNC connector and 100:1 voltage divider. It has a frequency response of 100 MHz and allows measurements with a maximum voltage of up to 2 kV. Hantek T3100
A probe for measuring AC and DC currents up to 65 A. It operates in a bandwidth of up to 20 kHz and can be connected to an oscilloscope via a BNC connector. Hantek CC-65
A probe for measuring AC and DC currents up to 650 A. It operates in a bandwidth of up to 400 Hz and can be connected to an oscilloscope via a BNC connector. Hantek CC-650
The housing for the DSO138 oscilloscope allows for easy storage and mobile use of the device. It protects the PCB and any microcircuits on it from dirt or accidental damage.
Universal oscilloscope probe with BNC connector. It has a voltage divider of 10:1 and offers a frequency response of 100 MHz. It allows measurements with a maximum voltage of up to 600 V. P6100
Oscilloscope probe designed for the analysis of signals generated by the ignition coil in automotive engines. It is compatible with most digital oscilloscopes. Hantek HT25
6-wire test leads that allow the oscilloscope to be connected to various components in the engine compartment without stripping or puncturing the insulation and without risking damage to the connectors. Hantek HT306-2.8mm
6-wire test leads that allow the oscilloscope to be connected to various components in the engine compartment without stripping or puncturing the insulation and without risking damage to the connectors. Hantek HT306-2.3mm
6-wire test leads that allow the oscilloscope to be connected to various components in the engine compartment without stripping or puncturing the insulation and without risking damage to the connectors. Hantek HT306-1.5mm
6-wire test leads that allow the oscilloscope to be connected to various components in the engine compartment without stripping or puncturing the insulation and without risking damage to the connectors. Hantek HT306-1.0mm
Cable (adapter) of a BNC connector to banana plugs. Allows convenient connection of the device to an oscilloscope, for example. Hantek HT30A
No product available!
Cable (adapter) of a BNC connector to banana plugs. Allows convenient connection of a device to an oscilloscope, for example. BNC Q9
Probe for measuring direct current up to 800 A and alternating current up to 500 A. Operates at 5 kHz and can be connected to an oscilloscope via a BNC connector. Powered via USB. Hantek CC-800
High-voltage differential probe. It has good measurement characteristics: a bandwidth of 50 MHz and an operating voltage of up to 1300 V. The probe has two attenuation coefficients: 50X and 500X. Hantek HT8050
No product available!