zł85.40 tax excl.
Current measurement module using the galvanically isolated Allegro ACS37200LLXTR-100B5 Hall-effect sensor. It provides a ±100 A bidirectional range, 150 kHz bandwidth, response time below 4 µs, and an extra-low current path resistance of approximately 0.05 mΩ. Pololu 5793
Current sensor module Pololu 5793 uses the Allegro ACS37200LLXTR-100B5 Hall-effect current sensor with a galvanically isolated current path. The device provides bidirectional current measurement from -100 A to +100 A. Measurement bandwidth reaches 150 kHz, while the response time is less than 4 µs.
Sensor operates from a 4.5–5.5 V supply, with 5 V nominal operation, and provides a sensitivity of 20 mV/A. The analog VOUT output is centered at 2.5 V at zero current and changes proportionally to the measured current. The VREF output provides a reference voltage, while the FAULT function enables detection of current exceeding a user-configurable threshold.
Large Carrier version uses a 6-layer PCB with 2 oz copper and provides convenient connection options for thick high-current wires or ring terminals. The sensor IC current path resistance is only about 0.05 mΩ, helping to reduce voltage drop and power losses. Minimum PCB creepage distance is 10.4 mm, and the board measures approximately 35.6 × 30.5 mm.
Manufacturer
Responsible person
The ACS71240 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 120 kHz) and low conduction resistance (0.6 mΩ), it minimizes energy loss and offers a fast response time of less than 5 µs. Pololu 5245
The ACS71240 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 120 kHz) and low conduction resistance (0.6 mΩ), it minimizes energy loss and offers a fast response time of less than 5 µs. Pololu 5246
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5252
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5253
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5254
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5255
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5256
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5257
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5258
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5259
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5260
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5262
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5263
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5270
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5271
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5272
Current measurement module using the galvanically isolated Allegro ACS37200LLXTR-100B5 Hall-effect sensor. It provides a ±100 A bidirectional range, 150 kHz bandwidth, response time below 4 µs, and an extra-low current path resistance of approximately 0.05 mΩ. Pololu 5793