The 0-5 A current sensor module based on the ACS712-05 system that uses the Hall effect to measure.
Manufacturer
Responsible person
The current measurement of 0 - 30A is carried out by the ACS712-30 system based on the Hall effect. The sensitivity of the system is 66mV / A (analog signal).
The current measurement with the value 0-20A is carried out by the ACS712-05 system based on the Hall effect. The sensitivity of the system is 100mV / A (analogue signal) .modACS712-20
Current sensor Pololu 5322 enables electrically isolated AC and DC current measurement in the range from -50 A to +50 A. The module is based on the Allegro CT432-HSWF50MR TMR sensor IC and provides up to 1 MHz bandwidth with an analog interface. Pololu 5322
Pololu 5323 current sensor provides electrically isolated AC and DC current measurement in the range of -65 A to +65 A. Based on the Allegro CT432-HSWF65MR sensor, the module uses TMR technology and offers a bandwidth of up to 1 MHz together with an analog interface. Pololu 5323
Pololu 5326 current sensor provides electrically isolated DC current measurement in the range of 0 A to 50 A. Based on the Allegro CT432-HSWF50DR sensor, the module utilizes TMR technology, offering a 1 MHz bandwidth and an analog interface. Pololu 5326
Pololu 5242 with the ACS71240KEXBLT-050B3 chip is a compact current sensor module for precision measurement applications in the ±50 A range. With galvanic isolation, fast response to current changes, and short-circuit detection capability, it is used in power systems, automotive and industrial electronics, and embedded projects. It is ideal for measuring currents in both DC and AC circuits while ensuring safety and accuracy.
Pololu 5328 current sensor provides electrically isolated DC current measurement in the range of 0 A to 70 A. Based on the Allegro CT432-HSWF70DR sensor, the module utilizes TMR technology, offering a 1 MHz bandwidth and an analog interface. Pololu 5328
Pololu 5333 current sensor provides electrically isolated AC and DC current measurement in the range of -50 A to +50 A. Based on the Allegro CT433-HSWF50MR sensor, the module utilizes TMR technology, offering a 1 MHz bandwidth and an analog output signal.
Pololu 5335 current sensor provides electrically isolated AC and DC current measurement in the range of -70 A to +70 A. Based on the Allegro CT433-HSWF70MR sensor, the module utilizes TMR technology, offering a 1 MHz bandwidth and an analog voltage output.
The module enables unidirectional AC and DC current measurement over a range from 0 A to 50 A. XtremeSense™ TMR technology, an electrically isolated current path, 1 MHz bandwidth, and an analogue voltage output support use in systems requiring fast current measurement and high dV/dt immunity. Pololu CT433-HSWF50DR Large Carrier 0–50 A, 3.3 V
The module enables unidirectional AC and DC current measurement over a range from 0 A to 65 A. XtremeSense™ TMR technology, an electrically isolated current path, 1 MHz bandwidth, and an analogue voltage output support use in systems requiring fast current measurement and high dV/dt immunity. Pololu CT433-HSWF65DR Large Carrier 0–65 A, 3.3 V
The INA3221 module, which allows simultaneous measurement of voltage and current for three power supplies via I2C with ±1% precision. With a 13-bit ADC and built-in 0.05Ω shunt resistors, it allows accurate monitoring of currents up to ±3.2A and voltages up to +26VDC. Adafruit 6062
HSTS08L 10A 2.5V Current Sensor. Enables measurement of high currents. modHSTS08L
No product available!
SCT010T-D 10A 5V AC Current Sensor. Enables measurement of high AC currents. modSCT010T-D
Compact current sensor based on TMR technology, enabling precise measurements up to 30 A with minimal energy losses. Thanks to a wide 1 MHz bandwidth, galvanic isolation and interference immunity, it is perfect for applications requiring fast response and high accuracy. Pololu 5317
Compact current sensor based on TMR technology, enabling precise measurements up to 20 A with minimal energy losses. Thanks to a wide 1 MHz bandwidth, galvanic isolation and interference immunity, it is perfect for applications requiring fast response and high accuracy. Pololu 5316
Compact current sensor based on TMR technology, enabling precise measurements up to 30 A with minimal energy losses. Thanks to a wide 1 MHz bandwidth, galvanic isolation and interference immunity, it is perfect for applications requiring fast response and high accuracy. Pololu 5305
Compact current sensor based on TMR technology, enabling precise measurements up to 20 A with minimal energy loss. Thanks to a wide 1 MHz bandwidth, galvanic isolation and interference immunity, it is perfect for applications requiring fast response and high accuracy. Pololu 5304
The current measurement with a value of 0 - 5A is realized by the ACS712-05 system based on the Hall effect. The system sensitivity is 185mV / A (analog signal).