Module with INA219 system with bi-directional current meter.
Manufacturer
Responsible person
The current measurement of 0 - 30A is carried out by the ACS712-30 system based on the Hall effect. The sensitivity of the system is 66mV / A (analog signal).
The current measurement with the value 0-20A is carried out by the ACS712-05 system based on the Hall effect. The sensitivity of the system is 100mV / A (analogue signal) .modACS712-20
Module with bi-directional current sensor based on the INA226 system. It allows you to measure current and power, works with a voltage of 0-36 V. It has an I2C interface.
A digital precision current sensor module that measures voltage, current and power of electronic modules and devices up to 26V and 8A with a relative error of ± 0.2%. DFRobot SEN0291
Pololu 5278 Large Carrier current sensor based on the ACS72981KLRATR-150B5 chip, designed for bidirectional current measurement from -150 A to +150 A with 5 V supply voltage in applications requiring galvanic isolation and an analog output signal. Pololu 5278
Current sensor in the Large Carrier version based on the ACS72981KLRATR-150U3 chip, designed for unidirectional current measurement from 0 A to 150 A with a 3.3 V supply voltage. The module uses Hall-effect sensing, an electrically isolated current path, and an analog output with a sensitivity of 17.6 mV/A proportional to the measured current. Pololu 5279
Current sensor in the Large Carrier version based on the ACS72981KLRATR-150U5 chip, designed for unidirectional current measurement from 0 A to 150 A with a 5 V supply voltage. The module uses Hall-effect sensing, an electrically isolated current path, and an analog output with a sensitivity of 26.7 mV/A proportional to the measured current. Pololu 5280
Current sensor in the Large Carrier version based on the ACS72981ELRATR-200B5 chip, designed for bidirectional current measurement from -200 A to +200 A with a 5 V supply voltage. The module uses Hall-effect sensing, an electrically isolated current path, and an analog output signal proportional to the measured current. Pololu 5282
Current sensor in the Large Carrier version based on the ACS72981ELRATR-200U3 chip, designed for unidirectional current measurement from 0 A to 200 A with a 3.3 V supply voltage. The module uses Hall-effect sensing, an electrically isolated current path, and an analog output signal proportional to the measured current. Pololu 5283
Precision Hall effect current sensor offering galvanic isolation, wide 150 kHz bandwidth and the ability to measure AC and DC current with very low power loss. With differential measurement and immunity to magnetic interference, it is perfect for applications requiring accurate current monitoring, such as power supplies, converters or motor control systems. Pololu 5290
Precision Hall effect current sensor offering galvanic isolation, wide bandwidth of 150 kHz and the ability to measure AC and DC current with very low power loss. Thanks to differential measurement and immunity to magnetic interference, it is perfect for applications requiring accurate current monitoring, such as power supplies, converters or motor control systems. Pololu 5291
Compact Pololu 5292 current sensor based on the ACS37220 IC, designed for measuring currents up to ±100 A at a 5 V supply voltage in applications requiring galvanic isolation and an analog output. Pololu 5292
Precision Hall effect current sensor offering galvanic isolation, wide bandwidth of 150 kHz and the ability to measure AC and DC current with very low power loss. Thanks to differential measurement and immunity to magnetic interference, it is perfect for applications requiring accurate current monitoring, such as power supplies, converters or motor control systems. Pololu 5293
Compact Pololu 5294 current sensor based on the ACS37220 IC, designed for measuring currents up to ±200 A at a 5 V supply voltage in applications requiring galvanic isolation and an analog output. Pololu 5294
Precision Hall effect current sensor offering galvanic isolation, wide bandwidth of 150 kHz and the ability to measure AC and DC current with very low power loss. Thanks to differential measurement and immunity to magnetic interference, it is perfect for applications requiring accurate current monitoring, such as power supplies, converters or motor control systems. Pololu 5295
Precision Hall effect current sensor offering galvanic isolation, wide 150 kHz bandwidth and the ability to measure AC and DC current with very low power loss. With differential measurement and immunity to magnetic interference, it is perfect for applications requiring accurate current monitoring, such as power supplies, converters or motor control systems. Pololu 5296
Large Carrier version current sensor from Pololu, model 5297, based on the ACS37220LEZATR-100B5 IC, designed for measuring current in the range from -100 A to +100 A at a 5 V supply in applications requiring galvanic isolation and analog output. Pololu 5297
Large Carrier version current sensor from Pololu, model 5298, based on the ACS37220LEZATR-150B5 IC, designed for measuring current in the range from -150 A to +150 A at a 5 V supply in applications requiring galvanic isolation and analog output. Pololu 5298
Large Carrier version current sensor from Pololu, model 5299, based on the ACS37220LEZATR-200B5 IC, designed for measuring current in the range from -200 A to +200 A at a 5 V supply in applications requiring galvanic isolation and analog output. Pololu 5299
Compact current sensor Pololu 5300 based on the CT432-HSWF20MR, designed for current measurement in the range from -20A to +20A at 5V supply in applications requiring galvanic isolation and analog voltage output. Pololu 5300
Module with INA219 system with bi-directional current meter