The 0-30A current sensor module based on the ACS712-30 system that uses the hall effect to measure.
Manufacturer BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Responsible person BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
The current measurement with the value 0-20A is carried out by the ACS712-05 system based on the Hall effect. The sensitivity of the system is 100mV / A (analogue signal) .modACS712-20
The current measurement with a value of 0 - 5A is realized by the ACS712-05 system based on the Hall effect. The system sensitivity is 185mV / A (analog signal).
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5263
Module with ACS724 current sensor with a measuring range of direct and alternating current from 0 to 10 A. It communicates via an analog interface. Pololu 4045
No product available!
The ACS72981 current sensor module uses the Hall effect to precisely and safely measure DC current while providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes power loss and offers a fast response time of less than 2 µs. Pololu 5284
Module with INA237 sensor designed for power monitoring. Allows measurement of voltages up to 85 VDC and current up to 10 A. Uses a 16-bit ADC for precise and accurate readings available via the I2C interface. Adafruit 6340
No product available!
Module with ACS724LLCTR-30AU current sensor with a measuring range of direct and alternating current from 0 to 30 A. It communicates via an analog interface. Pololu 4046
Module with an analog AC current sensor in a set with a probe for non-contact measurement of alternating current with a current of up to 10 A. DFRobot SEN0288
The current measurement with the value 0-20A is carried out by the ACS712-05 system based on the Hall effect. The sensitivity of the system is 100mV / A (analogue signal) .modACS712-20
Module with an analog AC current sensor in a set with a probe for non-contact measurement of alternating current with a current of up to 5A. DFRobot SEN0287
No product available!
Precision Hall effect current sensor offering galvanic isolation, wide bandwidth of 150 kHz and the ability to measure AC and DC current with very low power loss. Thanks to differential measurement and immunity to magnetic interference, it is perfect for applications requiring accurate current monitoring, such as power supplies, converters or motor control systems. Pololu 5295
A compact Hall-effect current sensor that provides accurate DC and AC current measurement within a ±10 A range with galvanic isolation. It features a high-sensitivity analog VOUT output with a 150 kHz bandwidth, enabling fast and precise readings in dynamic systems. The module operates over a wide temperature range of -40°C to 125°C, and the low current path resistance minimizes energy loss. Its small size and flexible mounting options make it ideal for prototyping, industrial systems, and space-constrained projects. Pololu 5446
No product available!
Module with an analog AC current sensor in a set with a probe for non-contact measurement of alternating current with a current of up to 20 A. DFRobot SEN0211
ACS711EX Current Sensor Carrier -31A to +31A
No product available!
This board is a simple carrier of Broadcom’s bidirectional ±50A ACHS-7125 Hall effect-based linear current sensor, which offers a low-resistance (~0.7 mΩ) current path and electrical isolation up to 3 kV RMS. Pololu 4034
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5261
The current measurement of 0 - 30A is carried out by the ACS712-30 system based on the Hall effect. The sensitivity of the system is 66mV / A (analog signal).