zł2,957.00 tax excl.
Probe for measuring direct and alternating current up to 30 A. Works in the band up to 50 MHz, can be connected to the oscilloscope through the BNC connector. Powered by USB. Micsig CP503B
Probe for measuring DC and AC current up to 30 A. Uses standard BNC interface and can be connected to an oscilloscope or a multimeter. It works in the frequency band up to 50 MHz, has two measuring ranges: 6 and 30 A. The probe can work with manual or automatic regulation and is powered by a USB connector. It can be used in industry, automotive electronics, power supplies and inverters. Dedicated to Micsig devices.
Manufacturer BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Responsible person BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
A portable tablet oscilloscope with a 10.1 inch LCD display and a touch screen. It has four channels and has good measurement parameters: 300 MHz bandwidth, 2 GSa/s sampling rate and 220 Mpts memory buffer. Micsig TO3004
A portable Smart oscilloscope with an 8-inch LCD display and a touch screen. It has two measurement channels and has good measurement parameters: 300 MHz band, 2 GSa/s sampling rate and 280 Mpts memory buffer. Micsig STO2302C
Probe for measuring direct and alternating current up to 30 A. Works in the band up to 50 MHz, can be connected to the oscilloscope through the BNC connector. Powered by USB. Micsig CP503B
No product available!
The Zeenko N 10 dB attenuator is a reliable accessory for any RF system user – from amateurs to professionals. It enables safe and precise measurements and provides better signal matching in the signal path. Thanks to its high durability (up to 5 W), it is suitable for a wide range of laboratory and field applications.
This current probe is designed for measuring DC and AC current in power electronics systems and switching power supplies. It offers a 10 MHz DC bandwidth, a rise time of ≤ 46 ns, and two measurement ranges: 30 A and 150 A RMS, with a maximum peak current of up to 300 A. The device provides high measurement accuracy of ±1% and a resolution of up to 10 mA in the lower range. The BNC connector ensures compatibility with many oscilloscopes, and the 20 mm jaws enable current measurements in larger wires. Micsig CP1510
No product available!
This current probe is designed for measuring DC and AC current in power electronics systems and switching power supplies. It offers a 5 MHz DC bandwidth, a rise time of ≤ 70 ns, and two measurement ranges: 50 A and 300 A RMS, with a maximum peak current of up to 500 A. The device provides high measurement accuracy of ±1% and a resolution of up to 10 mA in the lower range. The BNC connector ensures compatibility with many oscilloscopes, and the 20 mm jaws enable current measurements in larger wires. Micsig CP3005
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 60 A, offering a wide bandwidth from 70 Hz to 30 MHz and a sensitivity of 100 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP60XS-80
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 120 A, offering a wide bandwidth from 34 Hz to 30 MHz and a sensitivity of 50 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP120XS-80
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 300 A, offering a wide bandwidth from 10 Hz to 30 MHz and a sensitivity of 20 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP300XS-80
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 600 A, offering a wide bandwidth from 8 Hz to 30 MHz and a sensitivity of 10 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP600XS-80
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 1200 A, offering a wide bandwidth from 5 Hz to 30 MHz and a sensitivity of 5 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP1200XS-80
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 3000 A, offering a wide bandwidth from 4 Hz to 30 MHz and a sensitivity of 2 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP3000XS-80
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 6000 A, offering a wide bandwidth from 4 Hz to 30 MHz and a sensitivity of 1 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP6000XS-80
No product available!
Rogowski current probe designed for measuring high-amplitude AC currents up to 12,000 A, offering a wide bandwidth from 2 Hz to 30 MHz and a sensitivity of 0.5 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful for analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP12000XS-80
No product available!
Rogowski current probe designed for measuring very high-amplitude AC currents up to 300 A, offering a wide bandwidth from 10 Hz to 20 MHz and a sensitivity of 20 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP300XS-200
No product available!
Rogowski current probe designed for measuring very high-amplitude alternating currents up to 600 A, offering a wide bandwidth from 7 Hz to 20 MHz and a sensitivity of 10 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP600XS-200
No product available!
Rogowski current probe designed for measuring very high-amplitude AC currents up to 1200 A, offering a wide bandwidth from 5 Hz to 20 MHz and a sensitivity of 2 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP1200XS-200
No product available!
Rogowski current probe designed for measuring very high-amplitude alternating currents up to 6000 A, offering a wide bandwidth from 3 Hz to 20 MHz and a sensitivity of 1 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP6000XS-200
No product available!
Rogowski current probe designed for measuring very high-amplitude AC currents up to 120 A, offering a wide bandwidth from 14 Hz to 25 MHz and a sensitivity of 50 mV/A. Its near-zero impedance enables accurate measurements without affecting the circuit under test, which is useful in analyzing fast waveforms and power systems (MOSFETs, IGBTs, SiC, GaN). Micsig RCP120S-200
No product available!
Probe for measuring direct and alternating current up to 30 A. Works in the band up to 50 MHz, can be connected to the oscilloscope through the BNC connector. Powered by USB. Micsig CP503B