- Out-of-Stock

zł2,114.44 tax excl.
Test probe tip with 1000X attenuation factor. Dedicated to Micsig probes from the SigOFIT series operating in the 100 MHz and 200 MHz frequency bands. Micsig OP1000-2
Test probe tip with 1000X attenuation factor. It allows to increase the measuring range and is dedicated to Micsig probes from the SigOFIT series operating in the 100 MHz and 200 MHz frequency bands.
Manufacturer BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Responsible person BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Insulated fiber optic probe with a measuring range up to 2500 V. It works in the band up to 100 MHz, it can be connected to the oscilloscope via the BNC connector. Comes with a 10X attenuation tip. MOIP100P
No product available!
Insulated fiber optic probe with a measuring range up to 2500 V. It works in the band up to 200 MHz, it can be connected to the oscilloscope via the BNC connector. Micsig MOIP200P
No product available!
Rogowski-type current probe for precise measurements of alternating currents with a frequency of up to 30 MHz. Thanks to the flexible coil of 1.6 mm thickness and almost zero impedance introduced, it is ideal for work in hard-to-reach places of power systems. The integrated amplifier and BNC interface enable accurate measurements and easy integration with oscilloscopes, making it an ideal tool for R&D laboratories and power electronics services. Micsig RCP300XS
No product available!
Test probe tip with 20X attenuation factor. Dedicated to Micsig probes from the SigOFIT series operating in the 800 MHz and 1 GHz frequency band. Micsig OP20-1G
No product available!
High-voltage oscilloscope probe with BNC connector and 100:1 voltage divider. It has a frequency response of 100 MHz and allows measurements with a maximum voltage of up to 2 kV. Hantek T3100
Rogowski-type current probe for precise measurements of alternating currents with a frequency of up to 30 MHz. Thanks to the flexible coil of 1.6 mm thickness and almost zero impedance introduced, it is ideal for work in hard-to-reach places of power systems. The integrated amplifier and BNC interface enable accurate measurements and easy integration with oscilloscopes, making it an ideal tool for R&D laboratories and power electronics services. Micsig RCP3000XS
No product available!
The housing for the DSO138 oscilloscope allows for easy storage and mobile use of the device. It protects the PCB and any microcircuits on it from dirt or accidental damage.
A universal oscilloscope probe with a BNC connector and a 10:1 voltage divider. It has a frequency response of 60 MHz and allows measurements with a maximum voltage of up to 600 V. Hantek PP-80
No product available!
Micsig DP series differential probe based on advanced SigOFIT technology. It offers a 300 MHz frequency band and the ability to measure voltage up to 3000 V. It uses the popular BNC connector and is powered by a USB Type-C connector. Micsig DP3003
No product available!
The PP80B oscilloscope probe is a reliable tool for precise measurements, compatible with digital and analog oscilloscopes, offering a bandwidth of up to 80 MHz and the ability to select the attenuation factor. Hantek PP-80B
No product available!
Probe for measuring direct and alternating current up to 30 A. Works in the band up to 100 MHz, can be connected to the oscilloscope through the BNC connector. Powered by USB. Micsig CP1003B
Test probe tip with 2000X attenuation factor. Dedicated to Micsig probes from the SigOFIT series operating in the 350 MHz and 500 MHz frequency bands. Micsig OP2000-5
No product available!
Rogowski-type current probe for precise measurements of alternating currents with a frequency of up to 30 MHz. Thanks to the flexible coil of 1.6 mm thickness and almost zero impedance introduced, it is ideal for work in hard-to-reach places of power systems. The integrated amplifier and BNC interface enable accurate measurements and easy integration with oscilloscopes, making it an ideal tool for R&D laboratories and power electronics services. Micsig RCP120XS
No product available!
6-wire test leads that allow the oscilloscope to be connected to various components in the engine compartment without stripping or puncturing the insulation and without risking damage to the connectors. Hantek HT306-2.3mm
No product available!
Universal oscilloscope probe with BNC plug with 100: 1 voltage divider and 100 MHz bandwidth. It allows you to perform measurements with a maximum voltage of 2 kV
A probe tip with attenuation factor of 10000X. Dedicated to Micsig probes from the SigOFIT series operating in the 800 MHz and 1 GHz frequency band. Micsig OP10000-1G
No product available!
Micsig DP series differential probe based on advanced SigOFIT technology. It offers a frequency band of 100 MHz and the ability to measure voltage up to 1500 V. It uses the popular BNC connector and is powered by a USB Type-C connector. Micsig DP1500
No product available!
Universal oscilloscope probe with BNC connector and 10:1 voltage divider. It has a frequency response of 80 MHz and allows measurements with a maximum voltage of up to 600 V. Hantek PP-90
Test probe tip with 1000X attenuation factor. Dedicated to Micsig probes from the SigOFIT series operating in the 100 MHz and 200 MHz frequency bands. Micsig OP1000-2