zł33.03 tax excl.
Large Carrier version current sensor from Pololu, model 5297, based on the ACS37220LEZATR-100B5 IC, designed for measuring current in the range from -100 A to +100 A at a 5 V supply in applications requiring galvanic isolation and analog output. Pololu 5297
Large Carrier version current sensor from Pololu, model 5297, based on the ACS37220LEZATR-100B5, designed for measuring AC and DC current in the range from -100 A to +100 A at a nominal supply voltage of 5 V. Measurement is performed using the Hall effect in an isolated current path with very low resistance of approximately 0.1 mΩ, which minimizes power losses and reduces the impact of the sensor on the measured circuit.

The output signal is provided as an analog voltage proportional to the current, with a quiescent voltage level of approx. 2.5 V. The module offers bandwidth up to 150 kHz and response time below 4 µs, enabling monitoring of fast current changes in power electronics systems.
The sensor includes a FAULT output with configurable overcurrent threshold via the VOC pin, allowing fast detection of overloads and short circuits. The 6-layer PCB improves heat dissipation and stability during high-current operation. Additionally, integrated temperature compensation enhances measurement accuracy over a wide temperature range.
Manufacturer BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Responsible person BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
ACS714 Current Sensor Carrier -5 to +5A
ACS714 Current Sensor Carrier -30 to +30A
ACS711EX Current Sensor Carrier -31A to +31A
ACS711EX Current Sensor Carrier -15.5A to +15.5A
The current measurement of 0 - 30A is carried out by the ACS712-30 system based on the Hall effect. The sensitivity of the system is 66mV / A (analog signal).
No product available!
No product available!
No product available!
No product available!
No product available!
The current measurement with the value 0-20A is carried out by the ACS712-05 system based on the Hall effect. The sensitivity of the system is 100mV / A (analogue signal) .modACS712-20
The current measurement with a value of 0 - 5A is realized by the ACS712-05 system based on the Hall effect. The system sensitivity is 185mV / A (analog signal).
No product available!
Module with an analog AC current sensor in a set with a probe for non-contact measurement of alternating current with a current of up to 20 A. DFRobot SEN0211
The module with a TA12-200 current sensor with a measuring range of alternating current up to 5 A. The board is equipped with a Grove connector and communicates via an analog interface. Seeed Studio 101020027
Module with an analog current sensor. Enables measurement of alternating and direct current up to 20 A. DFRobot SEN0214
Module with INA219 system with bi-directional current meter
No product available!
Large Carrier version current sensor from Pololu, model 5297, based on the ACS37220LEZATR-100B5 IC, designed for measuring current in the range from -100 A to +100 A at a 5 V supply in applications requiring galvanic isolation and analog output. Pololu 5297