Module with a two-way Hall current sensor based on the ACS724LLCTR-20AB system. It allows you to measure the current in the range from -20 to 20 A. The board is powered with the voltage from 4.5 V to 5.5 V and is intended for use in circuits with a logical voltage of 5 V. It offers a current path with low resistance (~ 1.2 mΩ) and electrical insulation up to 2.4 kV RMS. The output is a proportional analog voltage (100 mV/A) centered at 2.5 V with an error of ± 0.8%.

The sensor requires five connections to work properly: input current (IP+ and IP-), logic power (VCC and GND) and sensor output (OUT). Pin FILTER allows you to adjust the bandwidth of the plate by adding a capacitor to ground in parallel with the 1 nF capacitor that is already on the board. Without an additional external filter capacitor, the frequency response is approximately 90 kHz.
Manufacturer BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Responsible person BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Module with an analog AC current sensor in a set with a probe for non-contact measurement of alternating current with a current of up to 20 A. DFRobot SEN0211
No product available!
Module with ACS724LLCTR-30AU current sensor with a measuring range of direct and alternating current from 0 to 30 A. It communicates via an analog interface. Pololu 4046
Module with an analog AC current sensor in a set with a probe for non-contact measurement of alternating current with a current of up to 5A. DFRobot SEN0287
A set of 40 pieces of female-female connecting cables in various colors, 10 cm long
No product available!
A set of 40 pcs of male-female connecting cables in various colors, 10 cm long
A set of 40 pcs of male-male connecting cables in various colors, 10 cm long
ACS724LLCTR-30AB current sensor module with a DC and AC measurement range from -30 to +30 A. It communicates via an analog interface. Pololu 4047
ACS724LLCTR-20AU current sensor module with a current measurement range from 0 to 20 A. It communicates via an analog interface. Pololu 4044
ACS724LLCTR-10AB current sensor module with a DC and AC measurement range from -10 to +10 A. It communicates via an analog interface. Pololu 4043
ACS724LLCTR-2P5AB current sensor module with a DC and AC measurement range from -2.5 to +2.5 A. It communicates via an analog interface. Pololu 4040
Module with INA228 sensor designed for power monitoring. It allows you to measure voltages up to 85 VDC and currents up to 10 A. It uses a 20-bit ADC converter, which guarantees very precise and accurate measurements available via the I2C bus. Adafruit 58332
No product available!
The ACS71240 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 120 kHz) and low conduction resistance (0.6 mΩ), it minimizes energy loss and offers a fast response time of less than 5 µs. Pololu 5240
The ACS71240 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 120 kHz) and low conduction resistance (0.6 mΩ), it minimizes energy loss and offers a fast response time of less than 5 µs. Pololu 5241
The ACS71240 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 120 kHz) and low conduction resistance (0.6 mΩ), it minimizes energy loss and offers a fast response time of less than 5 µs. Pololu 5243
The ACS71240 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 120 kHz) and low conduction resistance (0.6 mΩ), it minimizes energy loss and offers a fast response time of less than 5 µs. Pololu 5244
The ACS71240 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 120 kHz) and low conduction resistance (0.6 mΩ), it minimizes energy loss and offers a fast response time of less than 5 µs. Pololu 5245
The ACS71240 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 120 kHz) and low conduction resistance (0.6 mΩ), it minimizes energy loss and offers a fast response time of less than 5 µs. Pololu 5246
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5252
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5253
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5254
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5255
The ACS72981 current sensor module uses the Hall effect to accurately and safely measure AC and DC current, providing electrical isolation of the current path. With a wideband analog output (up to 250 kHz) and low conduction resistance (0.2 mΩ), it minimizes energy loss and offers a fast response time of less than 2 µs. Pololu 5256
Module with ACS724 current sensor with a measuring range of direct and alternating current from 0 to 10 A. It communicates via an analog interface. Pololu 4045