Main view
search
  • Main view
ID: 1182404
zł999.01
Tax included

zł812.20 tax excl.

A probe with a Rogowski coil dedicated to measuring current in a wide frequency range. Measurements can be made without modifying the circuit under test. Micsig RCP500

Delivery date unknown
Out-of-Stock

 

Free shipping

free shipping in Poland for all orders over 500 PLN

 

Same day shipping

If your payment will be credited to our account by 11:00

 

14 days for return

Each consumer can return the purchased goods within 14 days

Description

A probe with a Rogowski coil dedicated to measuring current in a wide frequency range. It is characterized by universal application, and at the same time it is easy to use in hard-to-reach parts of the circuit. The measuring coil is flexible, which means that measurements can be made without modifying the circuit under test. The probe is safe and convenient to use. It offers a current measurement of up to 500 A in the frequency range from 15 to 300 kHz. It is powered directly via the Micsig UPI interface or via USB for other oscilloscopes.

Features

  • Frequency band: 15 to 300 kHz (-3dB)
  • Current measurement range: 200 mApk to 500 Apk
  • Connector: BNC
  • Sensitivity: 10mV/A
  • Accuracy: 1%
  • Phase Accuracy: ≤0.8° (45Hz-66Hz)
  • Temperature coefficient: operating temperature range + 0.05 × accuracy / ℃ (23 ℃ ± 5 ℃)
  • Influence of external magnetic fields: 1.5% of full scale (400A / m, 50Hz / 60Hz)
  • Voltage error: ± 1mV
  • Maximum voltage: AC 10kV RMS (50Hz / 60Hz) (only part of Rogowski coil)
  • Output impedance: high resistance
  • Output noise: < 2mv rms
  • CUT Diameter: ≤Φ50mm
  • Power supply: DC 5V
  • Cable length: 2 m
  • Integrator dimensions: 37 x 22 x 82 mm
  • Rogowski coil inner diameter: 50 mm
  • Rogowski coil thickness: approx. Φ6mm
  • Working temperature: -20 to 70 ℃
  • Humidity: max. 80%
  • For indoor use

Kit contains

  • RCP500 current probe
  • USB cable
1182404