zł3,400.00 tax excl.
Rogowski-type current probe for precise measurements of alternating currents with a frequency of up to 30 MHz. Thanks to the flexible coil of 1.6 mm thickness and almost zero impedance introduced, it is perfect for work in hard-to-reach places of power systems. The integrated amplifier and BNC interface enable accurate measurements and easy integration with oscilloscopes, making it an ideal tool for R&D laboratories and power electronics services. Micsig RCP60XS
Micsig RCP is a Rogowski-type current probe designed for precise measurement of AC currents while maintaining a wide bandwidth up to 30 MHz. Thanks to its flexible, thin coil with a cross-section of only 1.6 mm, the device is perfect for hard-to-reach areas in electronic circuits, such as the leads of TO-220 transistors or other power semiconductors. The probe introduces almost zero input impedance, minimizing impact on the Device Under Test (DUT). An integrated amplifier powered by 12 V DC enables accurate measurement of highly dynamic, high-frequency signals.
The BNC interface allows for easy connection to any oscilloscope. The device offers a typical accuracy of 2% and excellent resistance to interference and high voltages up to 1 kVrms. The RCP probe is widely used in power electronics research—from switching current measurements in MOSFET and IGBT transistors to power quality analysis in inverters, UPS units, and SMPS systems. Its compact design and customizable coil parameters make it an invaluable tool for R&D labs and diagnostic departments.
Manufacturer BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Responsible person BTC Korporacja sp. z o. o. Lwowska 5 05-120 Legionowo Poland sprzedaz@kamami.pl 22 767 36 20
Rogowski-type current probe for precise measurements of alternating currents with a frequency of up to 30 MHz. Thanks to the flexible coil of 1.6 mm thickness and almost zero impedance introduced, it is ideal for work in hard-to-reach places of power systems. The integrated amplifier and BNC interface enable accurate measurements and easy integration with oscilloscopes, making it an ideal tool for R&D laboratories and power electronics services. Micsig RCP12000XS
No product available!
Rogowski-type current probe for precise measurements of alternating currents with a frequency of up to 30 MHz. Thanks to the flexible coil of 1.6 mm thickness and almost zero impedance introduced, it is ideal for work in hard-to-reach places of power systems. The integrated amplifier and BNC interface enable accurate measurements and easy integration with oscilloscopes, making it an ideal tool for R&D laboratories and power electronics services. Micsig RCP6000XS
No product available!
Rogowski-type current probe for precise measurements of alternating currents with a frequency of up to 30 MHz. Thanks to the flexible coil of 1.6 mm thickness and almost zero impedance introduced, it is ideal for work in hard-to-reach places of power systems. The integrated amplifier and BNC interface enable accurate measurements and easy integration with oscilloscopes, making it an ideal tool for R&D laboratories and power electronics services. Micsig RCP3000XS
No product available!
Rogowski-type current probe for precise measurements of alternating currents with a frequency of up to 30 MHz. Thanks to the flexible coil of 1.6 mm thickness and almost zero impedance introduced, it is ideal for work in hard-to-reach places of power systems. The integrated amplifier and BNC interface enable accurate measurements and easy integration with oscilloscopes, making it an ideal tool for R&D laboratories and power electronics services. Micsig RCP120XS
No product available!
Universal oscilloscope probe with BNC connector and 10:1 voltage divider. It has a frequency response of 80 MHz and allows measurements with a maximum voltage of up to 600 V. Hantek PP-90
A probe for measuring AC and DC currents up to 65 A. It operates in a bandwidth of up to 20 kHz and can be connected to an oscilloscope via a BNC connector. Hantek CC-65
No product available!
A probe tip with attenuation factor of 2000X. Dedicated to Micsig probes from the SigOFIT series operating in the frequency band of 100MHz, 200MHz and 350MHz. Micsig OP2000-3
No product available!
The Micsig DP series differential probe is based on advanced metal shielding technology. It offers a 100 MHz frequency bandwidth and the ability to measure voltages up to 7000 V. It uses the popular BNC connector and is powered by a USB Type-C connector. Micsig DP7000
No product available!
Oscilloscope Probes (pair). 460-004
Protective handbag designed for Micsig oscilloscopes of the TO, ATO and STO series.
The Hantek PP-300 is an oscilloscope probe with a bandwidth of 300 MHz, designed for precise measurement of high-frequency signals. It is compatible with a wide range of digital and analog oscilloscopes and features a switchable attenuation setting between 1× and 10×, allowing flexible adaptation to various applications. Thanks to its ergonomic design and robust construction, the probe offers user comfort and durability for everyday use in laboratory environments.
Oscilloscope probe designed for the analysis of signals generated by the ignition coil in automotive engines. It is compatible with most digital oscilloscopes. Hantek HT25
Insulated fiber optic probe with a measuring range up to 2500 V. It works in the band up to 350 MHz, it can be connected to the oscilloscope via the BNC connector. Comes with a 10X attenuation tip. Micsig MOIP350P
No product available!
Micsig MDP series differential probe based on advanced SigOFIT technology. It offers a frequency band of 500 MHz and the ability to measure voltage up to 1500 V. It uses the popular BNC connector and is powered by a USB Type-C connector. Micsig MDP1505
The Micsig P300 oscilloscope probe with a BNC connector offers a bandwidth of 300 MHz and a maximum input voltage of 600 V, enabling precise measurements of high-frequency and high-voltage signals. Its high input impedance minimizes impact on the circuit under test, ensuring measurement accuracy. The standard BNC connector ensures compatibility with most oscilloscopes, making it a versatile tool for laboratories and engineering applications.
Universal oscilloscope probe with BNC plug with 100: 1 voltage divider and 100 MHz bandwidth. It allows you to perform measurements with a maximum voltage of 2 kV
A probe tip with attenuation factor of 5000X. Dedicated to Micsig probes from the SigOFIT series operating in the frequency band of 100MHz, 200MHz and 350MHz. Micsig OP5000-3
No product available!
Rogowski-type current probe for precise measurements of alternating currents with a frequency of up to 30 MHz. Thanks to the flexible coil of 1.6 mm thickness and almost zero impedance introduced, it is perfect for work in hard-to-reach places of power systems. The integrated amplifier and BNC interface enable accurate measurements and easy integration with oscilloscopes, making it an ideal tool for R&D laboratories and power electronics services. Micsig RCP600XS
No product available!
A probe tip with attenuation factor of 10000X. Dedicated to Micsig probes from the SigOFIT series operating in the 500 MHz frequency band. Micsig OP10000-5
No product available!
Universal measurement probes for a multimeter. Compatible with all Micsig oscilloscopes. Micsig MS-A-005
Rogowski-type current probe for precise measurements of alternating currents with a frequency of up to 30 MHz. Thanks to the flexible coil of 1.6 mm thickness and almost zero impedance introduced, it is perfect for work in hard-to-reach places of power systems. The integrated amplifier and BNC interface enable accurate measurements and easy integration with oscilloscopes, making it an ideal tool for R&D laboratories and power electronics services. Micsig RCP60XS