The 0-20A current sensor module based on the ACS712-20 system that uses the Hall effect to measure.
Manufacturer
Responsible person
The current measurement of 0 - 30A is carried out by the ACS712-30 system based on the Hall effect. The sensitivity of the system is 66mV / A (analog signal).
The current measurement with a value of 0 - 5A is realized by the ACS712-05 system based on the Hall effect. The system sensitivity is 185mV / A (analog signal).
A compact Hall-effect current sensor that provides accurate DC and AC current measurement within a ±10 A range with galvanic isolation. It features a high-sensitivity analog VOUT output with a 150 kHz bandwidth, enabling fast and precise readings in dynamic systems. The module operates over a wide temperature range of -40°C to 125°C, and the low current path resistance minimizes energy loss. Its small size and flexible mounting options make it ideal for prototyping, industrial systems, and space-constrained projects. Pololu 5456
A compact Hall-effect current sensor that provides accurate DC and AC current measurement within a ±30 A range with galvanic isolation. It features a high-sensitivity analog VOUT output with a 150 kHz bandwidth, enabling fast and precise readings in dynamic systems. The module operates over a wide temperature range of -40°C to 125°C, and its low current path resistance (~1.6 mΩ) minimizes energy loss. Its small size and flexible mounting options make it ideal for prototyping, industrial systems, and space-constrained projects. Pololu 5453
A compact Hall-effect current sensor that provides accurate DC and AC current measurement within a ±10 A range with galvanic isolation. It features a high-sensitivity analog VOUT output with a 150 kHz bandwidth, enabling fast and precise readings in dynamic systems. The module operates over a wide temperature range of -40°C to 125°C, and its low current path resistance (~1.6 mΩ) minimizes energy loss. Its small size and flexible mounting options make it ideal for prototyping, industrial systems, and space-constrained projects. Pololu 5452
A compact Hall-effect current sensor that provides accurate DC and AC current measurement within a ±10 A range with galvanic isolation. It features a high-sensitivity analog VOUT output with a 150 kHz bandwidth, enabling fast and precise readings in dynamic systems. The module operates over a wide temperature range of -40°C to 125°C, and the low current path resistance minimizes energy loss. Its small size and flexible mounting options make it ideal for prototyping, industrial systems, and space-constrained projects. Pololu 5444
No product available!
A compact Hall-effect current sensor that provides accurate DC and AC current measurement within a ±10 A range with galvanic isolation. It features an analog VOUT output with a sensitivity of 132 mV/A and a 150 kHz bandwidth, enabling fast and precise readings in dynamic systems. The module operates over a wide temperature range of -40°C to 125°C, and the low current path resistance (~1.6 mΩ) minimizes energy loss. Its small size and flexible mounting options make it ideal for prototyping, industrial systems, and space-constrained projects. Pololu 5440
Crowtail – Electricity Sensor 2.0 enables precise measurement of alternating current up to 5 A, converting the signal into a 2 V analog voltage. Intended for energy monitoring projects and integration with microcontroller systems.
Crowtail – Current Sensor 2.0 enables AC/DC current measurement up to ±20 A using the ACS712 chip and generates an analog signal for further analysis. Used in energy-consumption monitoring systems, automation, and laboratory measurements.
Current measurement module using the galvanically isolated Allegro ACS37200LLXTR-100B5 Hall-effect sensor. It provides a ±100 A bidirectional range, 150 kHz bandwidth, response time below 4 µs, and an extra-low current path resistance of approximately 0.05 mΩ. Pololu 5793
Current measurement module with the galvanically isolated Allegro ACS37200LLXTR-200B3 Hall-effect sensor. It provides a ±200 A bidirectional range, 6.6 mV/A sensitivity, 150 kHz bandwidth, and a response time below 4 µs. The large carrier board facilitates high-current connections. Pololu 5792
Compact module for bidirectional current measurement using the galvanically isolated Allegro ACS37200LLXTR-100B5 Hall-effect sensor. It provides a ±100 A range, 20 mV/A sensitivity, 150 kHz bandwidth, and a response time below 4 µs. Pololu 5783
Compact module for bidirectional current measurement using the galvanically isolated Allegro ACS37200LLXTR-200B3 Hall-effect sensor. It provides a ±200 A range, 150 kHz bandwidth, response time below 4 µs, and an extra-low current path resistance of approximately 0.05 mΩ. Pololu 5782
Current measurement module using the galvanically isolated Allegro ACS37030LMYATR-065B3 sensor. A combination of Hall-effect sensing and an inductive coil provides DC to 5 MHz measurement bandwidth, a ±65 A range, and a typical response time of 40 ns. The larger carrier board facilitates high-current connections. Pololu 5699
Current measurement module using the galvanically isolated Allegro ACS37030LMYATR-040B3 sensor. A combination of Hall-effect sensing and an inductive coil provides DC to 5 MHz measurement bandwidth, a ±40 A range, and a typical response time of 40 ns. The larger carrier board facilitates high-current connections. Pololu 5698
Compact module for bidirectional current measurement using the galvanically isolated Allegro ACS37030LMYATR-065B3 sensor. A combination of Hall-effect sensing and an inductive coil provides DC to 5 MHz measurement bandwidth, a ±65 A range, and a typical response time of 40 ns. Pololu 5696
Compact module for bidirectional current measurement using the galvanically isolated Allegro ACS37030LMYATR-040B3 sensor. A combination of Hall-effect sensing and an inductive coil provides DC to 5 MHz measurement bandwidth, a ±40 A range, and a typical response time of 40 ns. Pololu 5695
Compact module for bidirectional current measurement using the galvanically isolated Allegro ACS37030LMYATR-025B3 sensor. A combination of Hall-effect sensing and an inductive coil provides DC to 5 MHz measurement bandwidth, a ±25 A range, and a typical response time of 40 ns. Pololu 5694
The current measurement with the value 0-20A is carried out by the ACS712-05 system based on the Hall effect. The sensitivity of the system is 100mV / A (analogue signal) .modACS712-20